#Construction design ·2024-10-26
Construction unit |
Information Technology Department of FJ |
||
Location |
Xiamen Sea Area |
Time |
2011.12-2012.1 |
Construction design |
1. Design of Changing the route. Select the relocated route of submarine optical fiber cables, design suitable turning points, organize route review, and apply for approval on behalf of the construction unit. |
||
2. Design of submarine optical fiber cables. Including capacity, length, model, spare parts, etc. |
|||
3. Channel protection construction design. Including a 6-meter deep burial design, burial techniques, and protection requirements for special sections. |
|||
Main parameters |
Cable model: ZTT SOFC-ASK430a/16B1 |
Outside Diameter: 36mm |
|
Number of cores:16 cores with double armor |
Weight per meter: 3.9kg/m |
||
Total length of cables:12km |
Laying depth:6.0m |
||
Water depth:16m |
Seabed sediments: Muddy sand, sand, silt |
||
Situation |
(1) Submarine cable loading and transportation. (2) Pull the submarine optical cable to joint wells (3) The laying construction of submarine optical cables in the middle sea area, with a embedding depth of over 6.0m throughout the entire process. (4) Salvage and recover the faulty submarine optical cable from Qingyu to Wuyu Island.And cut off the faulty submarine cables, add new cables, and carry on the installation of optical fiber splicing and joint box.Additional submarine cables and junction boxes are embedded at a depth of 3m. |
0086-021-6519 2621
Building 9, No. 98 Fulian 1st Road, Baoshan District, Shanghai
contactscoec@shanghaicable.cn
Official Account
link
0086-021-6519 2621
Calltop